Clearer fire-door classification. Stronger building safety. Better protection against heat.
The Government of India, through the Bureau of Indian Standards, notified Amendment No. 1 to IS 3614:2021 — Fire Doors and Doorsets — Specification in July 2023. The amendment brings clearer classification of fire doors based on integrity and insulation performance, helping architects, fire officers, consultants, builders and residents make more informed safety decisions.
Written for everyone who touches a fire door
During a fire, the danger is not only visible flame. Radiant heat and temperature rise on the non-fire side can increase risk for people evacuating, rescue teams operating nearby and property on the protected side.
A fully insulated fire door helps reduce heat transmission for the full rated duration, giving occupants, responders and building systems better protection during critical minutes.
It is not just about stopping fire. It is about stopping heat long enough to save lives.
The Gazette of India notification formally records Amendment No. 1 to IS 3614:2021, Fire Doors and Doorsets — Specification. The amendment was established on 3 July 2023, with the previous version without the amendment remaining in force only until 2 January 2024.
This matters because fire-door selection is no longer only about the number of minutes a door can resist flame passage. The amendment makes insulation performance visible through clear suffixes, so the difference between uninsulated, partially insulated and fully insulated doors is easier to identify.
A fire door is expected to act as part of a complete fire door assembly. IS 3614:2021 describes a fire door assembly as a combination of door, frame, hardware and accessories that together provide a specific fire-resistance rating in terms of integrity and insulation when installed in openings.
Earlier, many conversations around fire doors focused mainly on fire rating duration. But in real building safety, heat transmission can be equally critical. A door that maintains integrity but does not provide adequate insulation may still allow dangerous heat transfer to the non-fire side.
IntegrityIntegrity stops flame and hot gases.
InsulationInsulation limits temperature rise.
TogetherBoth matter when human life and evacuation safety are involved.
Ability of a separating element, when exposed to fire on one side, to prevent passage of flames and hot gases or occurrence of flame on the unexposed side.
Resistance to temperature rise on the unexposed face, up to a maximum of 180°C at any single point and a maximum average temperature of 140°C.
IS 3614:2021 was introduced as the first revision of the Indian Standard for Fire Doors and Doorsets. It widened the standard’s scope and covered product design, manufacturing, testing, supply, installation and compliance requirements.
Older provisions and evolving practices created limited clarity around insulation expectations and practical fire-door performance.
The 2021 standard comprehensively revised fire-door requirements. It covered fire-rated metal swing doors, wooden composite swing doors, metal sliding doors and metal rolling shutters, along with supply, installation and maintenance of fire door assemblies.
The insulation classification needed clearer communication. Fire doors with only minimum insulation and fire doors with full-duration insulation needed to be separated more transparently.
Amendment No. 1 introduced clearer classification language for uninsulated, partially insulated and fully insulated fire doors.
Architects, fire officers, consultants and builders can now specify fire doors with clearer understanding of whether the product is UD, PI or ID.
The amendment separates fire doors into three clear classifications based on insulation and integrity performance:
This makes the performance expectation visible in the fire-door designation itself.
Read a designation. Choose a suffix.
Flame resistance and heat protection for the full declared 120 minutes.
Every class below carries the same integrity rating. What changes is how long the safe side stays protected from heat. Pick a rating to see how each designation reads.
A fire door tested for integrity only, without requiring minimum insulation.
120 minutes integrity. No minimum insulation requirement, or insulation less than 30 minutes.
A door that is classified mainly for stopping flame and hot gases, not for full heat protection.
A fire door tested for both integrity and insulation, but with minimum insulation of 30 minutes.
120 minutes integrity. Minimum 30 minutes insulation.
A door where insulation is present, but only for the minimum required period, not for the full integrity duration.
A fire door tested for both integrity and insulation, where insulation rating is equal to the integrity rating.
120 minutes integrity. 120 minutes insulation.
A fire door designed to provide both flame resistance and heat protection for the full declared duration.
Insulation rails are drawn to scale against the selected integrity rating.
The amendment revised the classification table to clearly show uninsulated, partially insulated and fully insulated fire-door designations across 30, 60, 90, 120 and 180 minute ratings.
| Fire Resistance | Uninsulated Fire Door | Partially Insulated Fire Door | Fully Insulated Fire Door |
|---|---|---|---|
| 30 min | FD 30 UD | FD 30 PI | FD 30 ID |
| 60 min | FD 60 UD | FD 60 PI | FD 60 ID |
| 90 min | FD 90 UD | FD 90 PI | FD 90 ID |
| 120 min | FD 120 UD | FD 120 PI | FD 120 ID |
| 180 min | FD 180 UD | FD 180 PI | FD 180 ID |
PIFor PI classification, insulation is minimum 30 minutes.
IDFor ID classification, insulation rating is the same as the integrity rating.
The amendment updates definitions and removes ambiguity from classification language.
The test reference was updated from IS/ISO 3008-1 to IS 17518 Part 1 for fire resistance tests.
Fire doors are now classified as uninsulated, partially insulated and fully insulated.
Annex C was updated to state the tested product category as fully insulated, partially insulated or uninsulated fire door.
For hinged wooden fire doors, the maximum wall opening size shall not exceed 7.2 sq. m, with maximum permissible width of 2.4 m and height of 3.0 m. Doorsets shall be factory prepared for all hardware, and no work shall be carried out on doors at site.
IS 3614:2021 treats hardware as part of the fire door assembly and emphasizes the manufacturer’s role in ensuring intended performance.
Five points that decide whether the fire door installed on site still matches the fire door that was tested.
A fire door is only as good as the assembly that was tested. Changes made after testing can change its classification.
The fire resistance of a door assembly is determined by subjecting a full-size construction to test as per the applicable test procedure. The specimen should represent the assembly used in practice, including materials, method of construction, size, number of leaves, operation mode, glazing and essential hardware.
Additional tests may be required if there is a change in design, construction, infill material, size, vision glass, or if the time gap of testing exceeds five years.
Re-test window: 5 yearsVision panes should only be fitted under the control of the fire door manufacturer. Apertures should not be cut on-site.
No apertures cut on-siteFor insulated doors, glass area is more restricted. The maximum glass for insulated doors shall not exceed 0.06 sq. m.
Insulated doors: glass ≤ 0.06 sq. mFor hinged wooden fire doors, doorsets shall be factory prepared for all hardware, and no work shall be carried out on doors at site.
No work on doors at siteWhen preparing door schedules, it is no longer enough to mention only FD 60 or FD 120. The suffix matters. A specification should clearly state whether the door is UD, PI or ID, because each category communicates a different insulation expectation.
“Fire Rated Door: FD 120 ID as per IS 3614:2021 Amendment No. 1, with integrity and insulation for 120 minutes, complete with tested frame, hardware, seals and manufacturer-supported documentation.”
Door-schedule checklist
The amendment helps fire officers review fire-door proposals with clearer terminology. Instead of relying on generic claims, the classification suffix directly shows whether the fire door is uninsulated, partially insulated or fully insulated.
Review points
If the BOQ says FD 120, the next question should be: FD 120 UD, FD 120 PI or FD 120 ID? These are not the same. Procurement teams must understand the difference before finalizing vendors, rates and technical approvals.
Builder checklist
Residents do not need to become technical experts, but they can ask better questions. In a high-rise, hospital, hotel, school, mall or commercial building, fire doors are part of the life-safety system.
Questions residents can ask
Fire-door requirements vary depending on occupancy, risk level, evacuation strategy and authority requirements. The amendment gives clearer language to help stakeholders choose the right classification for the right application.
Staircases, lift lobbies, refuge areas and service zones require serious attention to fire-door performance.
Office towers, IT parks and business centres need properly classified doors to support compartmentation and safe evacuation.
Guest safety, corridor protection and back-of-house compartmentation must be supported by correctly specified fire doors.
Hospitals require higher life-safety sensitivity because occupants may have limited mobility.
Higher fire load areas demand careful selection of fire rating, door construction and installation details.
Airports, metro stations, malls and public buildings require clear documentation and authority-ready compliance.
FD 120 means everything is protected for 120 minutes.
Not always. FD 120 only tells you the fire rating duration. The suffix tells you whether it is UD, PI or ID.
Integrity and insulation are the same thing.
No. Integrity is about preventing flame and hot gas passage. Insulation is about limiting temperature rise on the unexposed side.
A partially insulated door gives full insulation.
No. PI means minimum insulation, typically 30 minutes, even if the integrity rating is higher.
Any site cutting or hardware change is acceptable.
No. The tested assembly matters. For hinged wooden fire doors, doorsets should be factory prepared for all hardware and no work should be carried out on doors at site.
Uninsulated doors are the same as fully insulated doors if the fire rating is same.
No. FD 120 UD and FD 120 ID are very different. FD 120 UD is based on integrity only, while FD 120 ID means both integrity and insulation for 120 minutes.
Use the official documents to understand the notified amendment, classification table and technical changes in detail.
Bureau of Indian Standards notification
Published in The Gazette of India, Extraordinary, Part III — Section 4.
Amendment to IS 3614:2021
Includes revised classification for uninsulated, partially insulated and fully insulated fire doors.
Fire Doors and Doorsets — Specification
The Indian Standard covering fire door assemblies, testing, installation and maintenance.
Our specification team answers project questions on door schedules, classifications and documentation.
+91 84200 50758IS 3614:2021 is the Indian Standard for Fire Doors and Doorsets — Specification. It covers requirements for fire door assemblies, including construction, testing, supply, installation and maintenance.
The amendment introduced clearer classification for fire doors as Uninsulated Fire Door, Partially Insulated Fire Door and Fully Insulated Fire Door, with suffixes UD, PI and ID.
FD 120 ID means the door has passed 120 minutes of integrity and minimum 120 minutes of insulation. Only then it is designated as FD 120 ID.
FD 120 PI means the door has passed 120 minutes of integrity and minimum 30 minutes of insulation.
FD 120 UD means the door has passed 120 minutes of integrity alone, with no insulation requirement or insulation less than 30 minutes.
Insulation helps limit temperature rise on the unexposed side of the door. This can reduce heat transfer and improve safety for people and property on the protected side.
For hinged wooden fire doors, the amended clause states that doorsets shall be factory prepared for all hardware and no work shall be carried out on doors at site.
Yes. The fire door assembly includes the door, frame, hardware and accessories that together provide the fire resistance rating.
Fire doors are not just products. They are life-safety systems. The July 2023 amendment to IS 3614:2021 gives India clearer language to distinguish between uninsulated, partially insulated and fully insulated fire doors.
When the right door is specified, tested, supplied and installed correctly, buildings become safer for occupants, responders, owners and communities.