Ratings, ISI marking, acoustic performance, lead-lining, installation, AMC — everything an architect, PMC, or facility owner asks before signing off a door schedule. Compiled from seven decades of project questions.
India's 1st ISI-marked fully insulated fire door · IS 3614:2023 · NABL-tested
Written by our technical team, updated against IS 3614:2023 and NBCS 2026. If your question isn't listed, our engineers respond on WhatsApp within 24 hours.
Tufwud manufactures two ISI-marked insulated fire door lines: FD60ID, rated for 60 minutes, and FD120ID, rated for 120 minutes. Both are supplied with the full test and certification documentation for your project file — ISI licence number, IS 3614:2023 test report, and BS 476 Part 22 test compliance where applicable.
A fire door can be rated for integrity alone — it holds back flame and smoke — or for integrity and insulation, meaning it also limits the temperature rise on the side away from the fire.
An insulated door keeps the escape route survivable for people passing it during evacuation. In a real fire, an integrity-only door's back surface can exceed 300°C, which is unsafe to touch. Tufwud insulated doors restrict the unexposed-side rise to 140°C above ambient — proper life-safety protection, not just a compliance label.
Tufwud was the first Indian manufacturer to carry an ISI mark for a fully insulated fire door.
IS 3614 is the Indian Standard covering fire check doors. An ISI mark is third-party certification by the Bureau of Indian Standards confirming that a product conforms to the relevant standard — with periodic factory audits, not just a one-time test.
Many PMCs, fire officers and government tenders ask for ISI-marked doors specifically. Under NBCS 2026, Part F Clause 2.22, the specification net has tightened further. Confirm the exact requirement with your fire consultant or the authority having jurisdiction for your building.
Tufwud acoustic and soundproof fire doors are engineered for sound insulation of up to 42 dB. Real-world performance depends on the door leaf construction, frame profile, seals and — critically — the installation detail. A door that tests at 42 dB in a lab can drop to 32 dB if the frame gap isn't sealed properly on site.
Share your target dB rating and use case (banquet hall, hospital consult room, recording studio, hotel corridor) with our technical team before finalising specs, and we'll match construction to acoustic goal.
Yes. Tufwud lead-lined doors provide radiation shielding for X-ray rooms, CT and radiology suites, MRI zones, cath labs, and oncology treatment areas. Lead thickness is specified project-by-project, typically between 1.5 mm and 3 mm, based on the physicist's shielding calculation.
Lead-lining can be combined with fire rating where the room also sits on a protected escape route — a common requirement in modern hospital compartmentation.
Beyond the fire-rated range:
Tufwud operates from its head office in Kolkata (Behala) with regional offices in Maharashtra, Delhi and Bengaluru, and manufacturing units in Kolkata, Surat and Rajasthan.
The company has served over 2,000 clients across more than 2,800 projects, with active supply across West Bengal, Maharashtra, Delhi, Karnataka, Gujarat, Sikkim, Odisha, Bihar, Jharkhand, Assam and the wider Northeast.
Yes. Tufwud offers end-to-end support:
Send us the building type, the fire rating your consultant has specified (FD60 / FD120), any acoustic or radiation requirement, and the approximate door quantity. Our technical team responds within 24 hours with a costed schedule.
Reach us on WhatsApp or call +91 84200 50758, or email sales@tufwud.com. For large projects, we're happy to visit site or host your consultant at the Behala factory.
Fire-rated, acoustic, lead-lined, glazed, metal, designer. Manufactured under IS 3614 with matched hardware and installation.
60-minute fully insulated wooden fire door with calcium silicate core. Hotel guest rooms, offices, apartment mains.
120-minute ISI-marked fully insulated fire door. Mandatory for stairwells, hospital compartmentation, high-rise.
Genuine combination — 38–42 dB sound insulation with FD60 or FD120 rating. Banquets, studios, hospital consults.
1.5–3 mm lead sheet for X-ray, CT, MRI and cath lab rooms. Combinable with fire rating for escape routes.
Certified fire-rated vision panels for hospital corridors, airports, modern offices. Compartmentation with sightlines.
Galvanised steel fire doors for basements, service shafts, transformer rooms and utility applications.
Send us your project brief — building type, fire rating specified, acoustic or radiation requirement, and door count. Our technical team responds within 24 hours.
Book a factory visit at our Behala unit — meet the engineers, inspect the seasoning yard, see the fire test rig.
+91 84200 50758
Sign in to your account