High-rise residential
Apartment main doors, lobby and staircase doors, electrical and service shaft doors for towers.
Pune · PCMC · MIDC belt
Tufwud makes India’s first fully ISI-marked, fully insulated fire door. Every doorset reaches Pune with leaf, frame, seals and hardware tested together as one assembly, plus the NABL evidence your PMC or PCMC fire NOC file needs.
Trusted byPune’s leading builders & institutionsPune fire NOC
Under the National Building Code and the Maharashtra Fire Prevention and Life Safety Measures Act, protected escape routes are an obligation, not a preference. A fire officer reviewing your fire NOC assesses the enclosure as a system, and one uncertified leaf breaks it.
Replacing a non-compliant doorset after plastering and flooring costs several times the correct product at procurement.
Check my door scheduleTypical ratings. Your approved fire scheme governs the final specification.
Ratings, explained
Ratings run 30, 60, 90 and 120 minutes. Two properties are measured separately, and integrity often outlasts insulation.
Same integrity, very different protection for people passing by.
Since 30 April 2026, NBCS 2026 permits only PI and ID doors on exit routes.
Why fully insulated mattersWhat we manufacture
Leaf, frame, seals and hardware are made and tested together at our own facility, then sized to your site opening, not to a catalogue.
FD120 IDStairwells · hospitals · high-rise
India’s first ISI-marked, fully insulated 2-hour fire door. 55 mm, asbestos-free, with twin calcium silicate boards.
FD60 IDFlats · hotel rooms · offices
Fully insulated 60-minute doorset with a calcium silicate core and treated hardwood framework.
GatemetPlant rooms · basements · shafts
Galvanised steel fire doors for industrial, basement, service-shaft and utility openings where wood is not suitable.
MahoveeReceptions · corridors · airports
Certified fire-rated glass in a tested bead system, where compartmentation has to coexist with sightlines.
38–42 dBHotels · theatres · studios
Sound insulation of 38–42 dB plus an FD60 or FD120 rating, with a rubber interlayer between calcium silicate boards.
Radiation shieldingX-ray · CT scan · cath labs
Fire-rated doors with an embedded 1.5 mm to 3 mm lead sheet for imaging suites and treatment zones.
Fire ratedHinges · closers · locks · panic
Rated hinges, closers, locks, panic devices and seals, tested with the door so the rating holds on site.
Every configuration ships as a complete doorset, rated as a whole.
Inside the doorset
A fire door is only as good as its weakest component. Every Tufwud doorset leaves the factory with all seven parts from the same tested configuration.
Ask for the actual report: laboratory, tested configuration, rating achieved and the hardware tested with it.
Request the test reportStandards and test evidence
Every Tufwud doorset is manufactured to Indian standards, and to international test standards where your consultant specifies them, with reports from a NABL-accredited laboratory. Ask, and we send the actual report.
Indian standards by default. International tests when the specification calls for them.
A certificate that names a laboratory but not a configuration proves nothing. Check that the hardware on your site matches the report.
Request the report for your project30+ approvals and certifications from government bodies, fire services and testing institutes






















Supply across Pune
With our own production line, we deliver across PMC and PCMC limits and the industrial corridors around them, from the first floor-wise drop to final handover.
One specification, one set of evidence. The same standard runs from our other operations, so multi-city developers do not re-qualify a supplier.
Price and installation
No single rate exists, and any supplier quoting one without seeing the schedule is guessing. Cost moves with rating, leaf construction, finish, glazing area and — usually the largest variable — hardware. A 120-minute glazed double leaf with panic hardware sits nowhere near a 30-minute flush leaf. Our guide to what a fire door costs sets out indicative ranges.
A correct doorset installed badly is not a rated doorset. Gaps out of tolerance, hollow grouting, closers removed, seals painted over — each shortens performance. We hand over an inspection checklist for verification at handover and annual re-checks.
Pick a door type, then change any option.
Illustrative and relative only. Send your door schedule for a firm price.
Industries we serve
From hospital wards and hotel corridors to cinema halls and high-rise homes, the same tested doorsets go into every kind of building. Here are a few of the projects that carry them.



Apartment main doors, lobby and staircase doors, electrical and service shaft doors for towers.

Fire doors for wards and corridors, lead-lined doors for imaging suites, acoustic doors for consultation rooms.

Corridor compartmentation, stairwell doors and server-room doors for commercial towers.

Fire-rated and acoustic fire-rated guest room doors, with corridor and stairwell compartmentation.

Acoustic fire doors with 38–42 dB sound insulation and an FD60 or FD120 rating, for screens, auditoriums and banquet halls.
Projects shown are from across India.
FAQ
Our engineers respond within 24 hours, with the standard or report behind the answer.
Ask a specification engineerSend us your door schedule
We would rather read your schedule than send a brochure. People comparing fire door manufacturers in Pune are really comparing evidence and delivery discipline. Share drawings, ratings and hardware requirements and you get:
+91 84200 50758
Tufwud BIM Library
IFC4, DWG and PDF door details, straight from tested Tufwud assemblies — place code-aligned doors in your model without redrawing them.
Have a question or feedback?
Fill out the form below, and we’ll respond promptly!
+91 84200 50758
Have a question or feedback?
Fill out the form below, and we’ll respond promptly!
+91 84200 50758
Sign in to your account