BIM Accelerator  /  Technical resources

IFC4 DWG IS 3614 NBCS 2026

13 objects · validated with IfcOpenShell

Fire door details, already drawn

Thirteen Tufwud door and barrier types, taken straight from the shop drawings and released as IFC4 objects with matching DWG and PDF details. Jamb sections, core build-up, seal positions and IS 3614 classification are already inside the file — place it, schedule it, and get on with the rest of the set.

  • 13 Door & barrier types
  • 3 IFC4 · DWG · PDF
  • 120min Fire rating · IS 3614
  • 1st Fully insulated ISI-marked FD

FD120ID-55-ISI.ifc

IFC4 · 1:20

CLIENT / RANGE TUFWUD · BIM ACCELERATOR First fully insulated ISI-marked FDTYPE CODE FD120ID-55-ISI IS 3614 · FD 120 IDSCALE 1:20 / 1:5 mmSTATUS RELEASED REV 03 2400 1200 A DETAIL A · JAMB · 1:5 SEALINSULATED CORE · 55 mm FRAME 120 × 70 mm Pset_Tufwud_FireDoor FIRE RATING 120 min IS 3614 CLASS FD 120 ID LEAF 55 mm FRAME 120 × 70 mm SEAL Intumescent ISI · BIS LICENCE max 1200 × 2400 0,0
Geometry from the shop drawings · modelled in mm 13 / 13 objects validated
  • ISI Mark · IS 3614
  • IFC4 · Property sets
  • DWG · Detail sheets
  • NABL · Accredited reports
  • NBCS 2026 · Documentation

Why this exists

The detail is already drawn. Use ours.

A fire door detail is not a creative decision — it is a tested assembly whose dimensions are fixed by the certificate. Redrawing it by hand introduces the one thing a fire door cannot tolerate: a discrepancy between the drawing and the tested product.

  1. 01 Filter

    Find the type you are specifying

    Filter by fire rating, narrow to ISI-marked only, or search by code, acoustic performance or lead lining. Every specification is on the card before you register.

  2. 02 Select

    Tick only the formats you need

    IFC4 for the model, DXF to place as a detail reference, PDF for the review set and the project record. Select as many types as the project needs in one pass.

  3. 03 Register

    Work email and organisation, once

    One registration covers the whole library. Links appear on screen immediately and a copy reaches your inbox, so the files are still there tomorrow.

  4. 04 Place

    Drop it in and keep drawing

    Ratings, core construction, frame section and seal specification arrive as structured properties, so the doorset schedules straight out of the model.

Drawing it by hand

Every project starts at zero

  • Jamb and head sections redrawn from a PDF catalogue, or traced from a previous job
  • Core build-up, intumescent seal position and rebate depth guessed or omitted
  • A generic door family carries no rating, so the schedule has to be typed by hand
  • Discrepancies surface at the fire NOC stage, when drawings are expensive to change
Time per type Hours
Data Typed by hand
Risk Carried to site

Using the library

Start from the tested assembly

  • Geometry follows the shop drawings, modelled in millimetres at the catalogue size
  • Rating, IS 3614 classification, core, frame and seals arrive as structured properties
  • A matching 2D detail in DXF and print-ready PDF, drawn from the same source
  • What you draw is what we manufacture, and what the certificate covers
Time per type Minutes
Data Schedules itself
Status Validated
Fire rating
Certification

Showing 13 of 13 types

Quick add
30 min

FD30ID-42

Insulated wooden composite fire door, acoustic build

  • IS 3614 FD 30 ID
  • Leaf 42 mm
  • Frame 100 × 55 mm
  • Performance Acoustic build (dB unpublished)
Choose formats to download
60 min

FD60ID-45

Fully insulated wooden composite fire door

  • IS 3614 FD 60 ID
  • Leaf 45 mm
  • Frame 120 × 60 mm
Choose formats to download
60 min ISI

FD60ID-45-ISI

ISI-marked fully insulated wooden composite fire door

  • IS 3614 FD 60 ID
  • Leaf 45 mm
  • Frame 120 × 60 mm
Choose formats to download
120 min

FD120ID-55

Fully insulated wooden composite fire door

  • IS 3614 FD 120 ID
  • Leaf 55 mm
  • Frame 120 × 70 mm
Choose formats to download
120 min ISI

FD120ID-55-ISI

ISI-marked fully insulated wooden composite fire door

  • IS 3614 FD 120 ID
  • Leaf 55 mm
  • Frame 120 × 70 mm
Choose formats to download
120 min

ACFD120ID-75

Acoustic fully insulated fire door

  • IS 3614 FD 120 ID
  • Leaf 75 mm
  • Frame 140 × 70 mm
  • Performance 42 dB (tested at ARAI)
Choose formats to download
42 dB

AC-75

Composite acoustic door (not fire rated)

  • IS 3614 Not fire rated
  • Leaf 75 mm
  • Frame 140 × 70 mm, double rebate
  • Performance 42 dB tested · 45 dB catalogue
Choose formats to download
120 min

LLFD120ID-57

Lead-lined fully insulated fire door

  • IS 3614 FD 120 ID
  • Leaf 57 mm
  • Frame 140 × 70 mm
  • Performance 2 mm Pb leaf
Choose formats to download
Pb

LL-44

Radiation-check lead-lined door (not fire rated)

  • IS 3614 Not fire rated
  • Leaf 44 mm
  • Frame 120 × 70 mm
  • Performance 2 mm Pb leaf
Choose formats to download
120 min

WGFD120-55-DBL

Wooden glazed fire door, double equal leaf

  • IS 3614 120 min, 3-criteria (Part 2)
  • Leaf 55 mm
  • Frame 120 × 70 mm LVL
  • Performance 2 leaves · 2327 × 2441 frame
Choose formats to download
120 min

FIREBARRIER-100

Fire barrier system for roof and ceiling voids

  • IS 3614 120 min fire barrier
  • Leaf 100 mm
  • Frame 50 × 100 mm
  • Performance IfcWall · 1200 × 1000 module
Files in preparation
E120

MAHOVEE-FD120PI-60

Mahovee fully glazed metal fire door (E120/EI30)

  • IS 3614 FD 120 PI
  • Leaf 60 mm
  • Frame 125 × 60 mm GI
  • Performance 38 dB min (glass)
Choose formats to download
120 min ISI

MFD120ID-46-ISI

Gatemet ISI-marked fully insulated metal fire door

  • IS 3614 FD 120 ID
  • Leaf 46 mm
  • Frame 143 × 57 mm GI, single rebate
Choose formats to download

Geometry follows the shop drawings, modelled in millimetres at the catalogue reference size and validated with IfcOpenShell before release. Dimensions shown are nominal.

One registration covers the whole library

Nothing selected yet

Links live 72 hours

Tufwud will never use these details to spam you.

01

Are the files free, and can I use them on a live project?

Yes to both. There is no charge and no licence fee. The objects are published so that what you draw matches what we manufacture — you may place them in any drawing set, tender package or model, including projects that ultimately use another supplier.

We ask only that you do not redistribute them as your own content, and that you keep the type codes intact so the doorset can be traced back to its test report.

02

Why do I have to register to get them?

Two honest reasons. First, so that we can tell you when a file changes — a revised detail, a new rating, or the native Revit families when they ship. A fire door detail that has quietly gone out of date inside your office template is a real problem, and we would rather be able to reach you.

Second, because knowing which practices are specifying which types is how we decide what to publish next. One registration covers the whole library; you will not be asked again.

03

Which software opens these files?

The IFC4 objects open in every mainstream BIM authoring tool and viewer:

  • Revit 2021 and later — Insert → Link IFC, or File → Open → IFC
  • ArchiCAD 24 and later — native IFC import, geometry and properties intact
  • Tekla Structures, BricsCAD BIM, BlenderBIM / Bonsai
  • Any IFC viewer for checking — Solibri, BIMcollab ZOOM, usBIM, Navisworks

The DWG details open natively in AutoCAD, and in BricsCAD, ZWCAD, DraftSight and any DWG-compatible CAD. They can be placed as a drafting view or attached as an external reference. The PDFs are print-ready at A3.

If your office standard is DXF rather than DWG — or you are on a tool that only reads DXF — ask and we will send the same detail in that format.

04

Are there native Revit families (.rfa)?

Not yet, and we would rather say so plainly. The authoring specification, shared parameter file and type catalogues for five families covering all thirteen products are complete. The families themselves have not been released.

Until they are, the IFC objects import into Revit but arrive at a fixed size and are not wall-hosted. Use them for coordination, clash checking and schedule data — not as parametric door families you resize per opening. Tick the box on the registration form and you will get one email when they ship, and nothing else on that list.

05

What data is inside the IFC objects?

Each object carries its fire rating, IS 3614 classification, core construction, frame section and seal specification as structured properties, alongside the standard Pset_DoorCommon set. The doorset schedules directly out of the model instead of being typed in by hand, and the data round-trips when the model is exchanged.

Geometry follows the shop drawings, is modelled in millimetres at the catalogue reference size, and is validated with IfcOpenShell before release.

06

My project needs a size or configuration that is not in the library

Expected — the library is published at catalogue reference sizes, and most projects need something else. Send the opening schedule and we will confirm what is achievable within the tested range, then issue a project-specific detail.

Note that ISI-marked doorsets are covered by a BIS licence up to 1200 × 2400 mm; beyond that the doorset is supplied against its test report rather than the ISI mark, and we will say which applies before you specify it.

07

How long do the download links stay live?

72 hours. After that, request a fresh copy with the same email address — there is no second registration and no waiting. A copy of every link is also emailed to you at the time of the request, so the files stay reachable from your inbox.

08

Does using these objects commit me to Tufwud as the supplier?

No. There is no obligation attached to the download, and we do not treat it as one.

What we would ask is that if the drawing carries our detail, the doorset that gets installed matches it. A tested assembly is only worth what the built assembly reproduces — substituting an uninsulated leaf into a detail drawn for a fully insulated one leaves the certificate behind, and under NBCS 2026 it leaves compliance behind too.

Specifying a project now

The drawing is the easy part. Get the doorset right.

Send us the opening schedule and we will confirm ratings, sizes and ISI coverage against the tested range before it reaches the fire NOC stage — not after. Delhi NCR, Mumbai, Kolkata, and every project in between.

Fill Up the Form

Get in Touch

Have a question or feedback?